EasyManua.ls Logo

Siemens SCALANCE XR-300WG - No Ring-Redundancy Standby; Commands in the Redundancy Configuration Mode

Siemens SCALANCE XR-300WG
618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8.4.5.7 no ring-redundancy standby
Description
With this command, you disable the standby function.
Requirement
HRP is enabled
You are in the Global configuration mode.
The command prompt is:
cli(config)#
Syntax
Call the command without parameters:
no ring-redundancy standby
Result
The standby function is disabled.
Further notes
You enable the setting with the ring-redundancy standby command.
You can display the status of this function and other information with the show ring-
redundancycommand.
8.4.6 Commands in the redundancy configuration mode
This section describes commands that you can call up in the Redundancy Configuration mode.
In the Global Configuration mode, enter the ring-redundancy configuration command
to change to this mode.
If you exit the Redundancy Configuration mode with the exit command, you return to the
Global Configuration mode.
If you exit the Redundancy Configuration mode with the end command, you return to the
Privileged EXEC mode.
Layer 2 management protocols
8.4 Ring redundancy and standby connection
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06 399