Result
"disable" is activated for the loopd reaction remote function.
"disable" is the default after enabling loop detection.
Further notes
You enable the "no action" reaction with the no loopd reaction remote command.
You can display the status of this function and other information with the show loopd
command.
See also
Addresses and interface names (Page 36)
12.6.3.8 no loopd reaction remote
Description
With this command, you enable the "no action" reaction for a remote loop. If a remote loop is
detected, this has no effect on the port.
Requirement
loopd is enabled
You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no loopd reaction remote
Result
"no action" is activated for the loop reaction remote function.
"disable" is the default after enabling loop detection.
Further notes
You enable the "disable" setting with the loopd reaction remote command.
You can display the status of this function and other information with the show loopd
command.
Diagnostics
12.6 Loop detection
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06 609