EasyManuals Logo

Siemens SCALANCE XR-300WG User Manual

Siemens SCALANCE XR-300WG
618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #541 background imageLoading...
Page #541 background image
Diagnostics
12
The monitoring of the system and error diagnostics are handled in different ways:
Events and faults handling:
Predefined events generate a message. These messages can be distributed in different
ways:
Entry in the local log
Transfer to the Syslog server
Sending as e-mail
Sending as SNMP trap
Syslog:
Configures the transfer to the Syslog server
Remote Monitoring (RMON):
Variables of the Management Information Base are monitored for the violation of limit values
and messages are generated if they do. These messages are collected and can be
distributed in the following ways:
Entry in the local log
Sending as SNMP trap
Transfer to the Syslog server
Transfer to a network management station using SNMP
Port mirroring:
Mirroring of ports to analyze the data stream without disturbing operation
Loop detection:
Detection and elimination of damaging loops. Loops in the network can cause total failure
of the transfer and must be detected and eliminated.
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06 541

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals