The parameters have the following meaning:
Parameter Description Range of values/note
destination-
address
Address of the called node Enter a valid IPv4 address or a valid
host name.
size Keyword for the size of the packets to be
transferred
-
byte Keyword for the size of the packets in bytes 0 … 2080
count Keyword for the number of packets to be re‐
quested
-
packet_count Number of packets 1 … 10
timeout Response wait time
If this time expires, the request is reported
as "timed out".
-
seconds Time to the timeout in seconds 1 … 100
For information on names of addresses and interfaces, refer to the section "Addresses and
interface names (Page 36)".
If you do not select any parameters from the parameter list, the default values are used.
At system start or when using the restart command with the option memoryor factory,
the following defaults apply:
Parameter Default value
size 32
count 3
timeout 1
Result
The messages relating to the response of the called node are displayed.
3.1.9 Commands in the global configuration mode
This section describes commands that you can call up in the Global configuration mode.
In Privileged EXEC mode, enter the configure terminal command to change to this mode.
Commands relating to other topics that can be called in the Global configuration mode can be
found in the relevant sections.
You exit the Global configuration mode with the end or exit command and are then in the
Privileged EXEC mode again.
Configuration
3.1 System
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
64 Configuration Manual, 07/2017, C79000-G8976-C361-06

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals