5.2.3.2 no ntp server
Description
With this command, you delete the connection to a server on the NTP client.
Requirement
You are in the NTP configuration mode.
The command prompt is as follows:
cli(config-ntp)#
Syntax
Call the command without parameter assignment:
no ntp server
Result
The connection to a server is deleted on the NTP client.
Further notes
You configure the connection to a server with the ntp server command.
5.2.3.3 ntp time diff
Description
With this command, you configure the time difference between the device and the NTP server.
Requirement
You are in the NTP configuration mode.
The command prompt is as follows:
cli(config-ntp)#
Syntax
Call up the command with the following parameters:
ntp time diff <(+/-hh:mm)>
System time
5.2 NTP client
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
152 Configuration Manual, 07/2017, C79000-G8976-C361-06