EasyManua.ls Logo

Siemens SCALANCE XR-300WG - Sender Mail-Address

Siemens SCALANCE XR-300WG
618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
cli(config-events)#
Syntax
Call up the command with the following parameters:
no smtp-server ipv4 <ucast_addr>
The parameter has the following meaning:
Parameter Description Range of values
ipv4 Keyword for an IPv4 address -
ucast_addr Value for an IPv4 address Enter a valid IPv4 address.
For information on names of addresses and interfaces, refer to the section "Addresses and
interface names (Page 36)".
Result
The SMTP server entry is deleted.
Further notes
You configure an e-mail server entry with the smtp-server command.
7.6.2.3 sender mail-address
Description
With this command, you configure the e-mail name of the sender.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
sender mail-address <mail-address>
The parameter has the following meaning:
Parameter Description Range of values / note
mail-address Email name of the sender max. 100 characters
Network protocols
7.6 SMTP client
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
354 Configuration Manual, 07/2017, C79000-G8976-C361-06

Table of Contents

Related product manuals