EasyManua.ls Logo

Siemens SCALANCE XR-300WG - Rmon Event

Siemens SCALANCE XR-300WG
618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no rmon alarm <number (1-250)>
The parameter has the following meaning:
Parameter Description Range of values / note
number Number of the alarm to be deleted 1 ... 250
Result
The entry for monitoring a MIB variable is deleted.
12.4.2.5 rmon event
Description
With this command, you configure an event in the RMON Event Table.
You specify a description and the person responsible and specify which SNMP notification is
generated. You can configure the sending of traps globally with the command snmp
notify.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
rmon event <number(1-500)>[description<event-description(127)>]
[owner<ownername(127)>][trap<notify(127)>]
The parameters have the following meaning:
Parameter Description Range of values / note
number Number of the event 1 ... 500
description Keyword for a description -
Diagnostics
12.4 RMON
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06 581