EasyManuals Logo

Siemens SCALANCE XR-300WG User Manual

Siemens SCALANCE XR-300WG
618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #403 background imageLoading...
Page #403 background image
The parameters have the following meaning:
Parameter Description
interface-type Specifies the interface type for the first ring port
interface-id Specifies the number of the interface for the first ring port
interface-type Specifies the interface type for the second ring port
interface-id Specifies the number of the interface for the second ring port
For information on names of addresses and interfaces, refer to the section "Addresses and
interface names (Page 36)".
Note
Differing port addresses
The first and second port must be configured on different interfaces.
Result
The ports of the ring redundancy are configured.
8.4.6.4 standby connection-name
Description
With this command, you assign a name to the standby connection on the device.
Requirement
You are in the Redundancy configuration mode.
The command prompt is as follows:
cli(config-red)#
Syntax
Call up the command with the following parameters:
standby connection-name <string(32)>
The parameter has the following meaning:
Parameter Description Range of values / note
<string(32)> Name of the connection max. 32 characters
Result
The standby connection is assigned a name.
Layer 2 management protocols
8.4 Ring redundancy and standby connection
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06 403

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals