6.3.5.5 spanning-tree bpdu-transmit
Description
With this command, you enable or disable the BPDU transmit status at the port.
Requirement
You are in the Interface Configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
spanning-tree bpdu-transmit{enabled|disabled}
The parameters have the following meaning:
Parameter Description Range of values / note
enabled BPDU packets are transmitted at the
port
Default: enabled
disabled BPDU packets are not transmitted at
the port
-
Result
The BPDU transmit status has switched over.
Further notes
You can display the status of this function and other information with the show spanning-
tree interface command with the detail option.
Network structures
6.3 Spanning Tree
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
246 Configuration Manual, 07/2017, C79000-G8976-C361-06