Result
The spanning tree function is enabled.
If you enable Spanning Tree, passive listening is disabled.
Further notes
The default setting of the function with PROFINET variants is "disabled".
The default setting of the function with EtherNet/IP variants is "enabled".
You disable the ring redundancy function with the no ring-redundancy command.
You disable the spanning tree function with the no spanning-tree command.
You can display the status of this function and other information with the show spanning-
tree detailcommand.
You can display information about active ports with the show spanning-tree active
command.
6.3.4.2 no spanning-tree
Description
With this command, you disable the spanning tree function.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no spanning-tree
Result
The spanning tree function is disabled.
Further notes
You enable the spanning tree function with the spanning-tree command.
You can display the status of this function and other information with the show spanning-
tree detailcommand.
Network structures
6.3 Spanning Tree
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06 229

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals