Further notes
You enable this function with the panel-button control-faultmask command.
4.3.1.5 panel-button control-hsr-manager
Description
With this command, you enable the following function of the button:
If display mode B is displayed and the button is pressed for 5 seconds, the "redundancy
manager" function is switched over.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameter assignment:
panel-button control-hsr-manager
Result
The function of the button for switching over the redundancy manager is enabled.
Further notes
You disable this function with the no panel-button control-hsr-manager command.
4.3.1.6 no panel-button control-hsr-manager
Description
With this command, you disable the following function of the button:
If display mode B is displayed and the button is pressed for 5 seconds, the "redundancy
manager" function is switched over.
Requirement
You are in the Global configuration mode.
The command prompt is as follows: