3.1.10.9 media type
Description
With this command, you configure the mode of a combo port.
Note
This command only influences combo ports.
If you attempt to configure a different port with this command, an error message will be
displayed.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
media-type {auto|rj45|sfp}
Configuration
3.1 System
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface