EasyManua.ls Logo

Siemens SCALANCE XR-300WG - No Dot1 X Port-Control

Siemens SCALANCE XR-300WG
618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Result
The port control parameter is configured.
Further notes
You can reset the port control parameter to the default with the no dot1x port-control
command.
You can display the status of this function and other information with the show
dot1xcommand.
11.5.3.14 no dot1x port-control
Description
With this command, you reset the port control parameter of the authenticator to the default
value.
The default value is force-authorized.
With this, data traffic is permitted without restrictions.
Requirement
You are in the Interface Configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no dot1x port-control
Result
The port control parameter of the authenticator is reset to the default value.
Further notes
You configure the port control parameter with the dot1x port-control command.
You can display the status of this function and other information with the show
dot1xcommand.
Security and authentication
11.5 Port Based Network Access Control
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
538 Configuration Manual, 07/2017, C79000-G8976-C361-06