Further notes
You reset the common agent address to the default value with the no ip dhcp relay
common-agent-address-interface command.
You enable the use of a common agent address with the ip dhcp relay common-agent-
address command.
You disable the use of a common agent address with the no ip dhcp relay common-
agent-address command.
7.4.2.9 no ip dhcp relay common-agent-address-interface
Description
With this command you reset the common agent address to the default value.
Requirement
You are in the Global configuration mode.
The command prompt is:
cli(config)#
Syntax
Call the command without parameter assignment:
no ip dhcp relay common-agent-address-interface
Result
The default value for the common agent address is used.
Further notes
You define a common agent address with the ip dhcp relay common-agent-address-
interface command.
You enable the use of a common agent address with the ip dhcp relay common-agent-
address command.
You disable the use of a common agent address with the no ip dhcp relay common-
agent-address command.
7.4.2.10 service dhcp-relay
Description
With this command, you enable the DHCP relay agent on the device. The DHCP relay agent
forwards DHCP queries to DHCP servers located in a different subnet.
Network protocols
7.4 DHCP Relay
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
316 Configuration Manual, 07/2017, C79000-G8976-C361-06