3.1.10.14 shutdown
Description
With this command, you shut down the interface.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
shutdown [complete]
The parameter has the following meaning:
Parameter Description Range of values / note
without parame‐
ters
The interface is disabled but the connection remains. -
complete The interface is disabled and the connection to the part‐
ner device is terminated.
For every optical port that
you disable with the
shutdown complete
command, the current con‐
sumtion of the device is re‐
duced by 30 mA.
Result
The Interface is shut down.
If you execute this command without parameters, a connection remains displayed. The LED
for the port status flashes. However no data is sent or received.
Further notes
You activate the interface with the no shutdown command.
You can display the status of this function and other information with the show
interfacescommand.
3.1.10.15 no shutdown
Description
With this command, you shut down an interface.
Configuration
3.1 System
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
86 Configuration Manual, 07/2017, C79000-G8976-C361-06

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals