cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
dot1x mac-auth port [mac <aa:aa:aa:aa:aa:aa>] reset
The parameters have the following meaning:
Parameter Description Range of values / note
mac Keyword for a MAC address -
aa:aa:aa:aa:aa:aa MAC address of the interface aa:aa:aa:aa:aa:aa
Result
MAC authentication is reset for the port.
11.5.3.10 dot1x mac-auth vlan-assign
Description
With this command you enable the assignment of the VLAN ID for a MAC address by the
RADIUS server.
The port can only be assigned to the VLAN, if the VLAN has been created on the device.
Otherwise Authentication is rejected.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
dot1x mac-auth vlan-assign
Result
The VLAN ID for a MAC address is assigned by the RADIUS server.
Further notes
You disable the assignment of the VLAN ID for a MAC address by the RADIUS server with
the no dot1x mac-auth vlan-assign command.
Security and authentication
11.5 Port Based Network Access Control
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06 535

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals