Parameter Description Range of values / note
detect-threshold Keyword for the threshold value -
integer Specifies the threshold value after how
many received loop detection frames, a
loop is assumed and the device reacts
according to the setting.
1 ... 500
Default: 2
reaction-timeout Keyword for the time to the end of the
reaction time
-
seconds Specifies the number of seconds after
which the device automatically changes
to the status in which it was before the
loop.
0 ... 86400
Default: 0
If you set the value "0", you need
to enable the port manually again
following a loop using the com‐
mand loopd port reset.
If you do not select any parameters from the parameter list, the default value is used. The
default values apply only to a port enabled earlier with loopd sender.
Result
The settings are suitably configured.
Further notes
You can display the status of this function and other information with the show loopd
command.
12.6.3.3 loopd port reset
Description
With this command, you enable a port that was blocked by loop detection.
Requirement
Loop detection is enabled
You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
loopd port reset
Diagnostics
12.6 Loop detection
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06 605

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals