Syntax
Call the command without parameters:
no ring-redundancy
Result
The ring redundancy function is disabled.
Further notes
You enable the ring redundancy function with the ring-redundancy mode command.
8.4.5.6 ring-redundancy standby
Description
With this command, you enable the standby function.
Requirement
HRP is enabled
You are in the Global configuration mode.
The command prompt is:
cli(config)#
Syntax
Call the command without parameters:
ring-redundancy standby
Result
The standby function is enabled.
Further notes
You disable the setting with the no ring-redundancy standby command.
You can display the status of this function and other information with the show ring-
redundancycommand.
Layer 2 management protocols
8.4 Ring redundancy and standby connection
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
398 Configuration Manual, 07/2017, C79000-G8976-C361-06