12.1.8.2 client config
Description
With this command, you enable one of the clients that processes or forwards the messages
of the device.
The following clients are available:
syslog: sends the messages to the Syslog server
trap: sends the messages as SNMP trap to a configured recipient
email: sends the messages as e-mail
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
client config {syslog|trap|email|all}
The parameters have the following meaning:
Parameter Description
syslog Enables the client that sends the messages to the Syslog server
trap Enables the client that sends the SNMP traps
email Enables the client that sends the e-mails
all Enables all clients at once
Result
The function of the client selected for the transfer is enabled.
Further notes
You display the status of the events and the clients with the show events config command.
You disable a client with the no client config command.