EasyManuals Logo

Siemens SCALANCE XR-300WG User Manual

Siemens SCALANCE XR-300WG
618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #332 background imageLoading...
Page #332 background image
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
snmp access <GroupName> {v1|v2c|v3 {auth|noauth|priv}}
[read <ReadView|none>][write <WriteView|none>][notify <NotifyView|
none>]
[{volatile|nonvolatile}]
The parameters have the following meaning:
Parameter Description Range of values / note
GroupName Name of the group to which access is
configured
max. 32 characters
Version Selects the version of the protocol used
v1
v2c
v3
Authentication Selects the authentication method.
auth
Enables MD5 or SHA as
authentication method
noauth
No authentication
priv
Enables authentication and
encryption
read The data can be read.
Keyword
ReadView
none
write The data can be read and written
Keyword
WriteView
none
notify Changes can be sent as a tag.
Keyword
NotifyView
none
Storage Type Specifies whether the settings remain
following a restart.
volatile :
The settings are lost after a
restart
nonvolatile :
The settings are retained after
a restart
The keywords need to be specified.
If optional parameters are not specified when configuring a group, the default value will be
used.
Result
The settings for access to an SNMP group are configured.
Network protocols
7.5 SNMP
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
332 Configuration Manual, 07/2017, C79000-G8976-C361-06

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals