134
4 Adjusting knitting machine
Basic settings
Stitch ten sion (Setup2)
Stitch tension (Setup2)
NP 1-100 (tab) stp
Further information:
Stitch Tension Range [513]
Stitch lengths [515]
Economic production and the influe
ncing factor
s [511]
Explanation
Value range
NPK
Correction for all stitch cams
Minimum value: -2
Maximum value: 2
Step width: 0.05
NP1 -
NP100
Stitch cam position 1 to 100
Value
Stitch length in NP values or mm
Value [mm]
Specification in NP values.
Minimum value: 6.5
Maximum value: 22.5
Step width: 0.05
Value [mm]
Settings in millimeters.
Setting the yarn length per stitch
(Yarn Length Control).
Minimum value: 2.20
Maximum value: 33.00
Step width: 0.01