6 Maintenance of the knitting machine
Lubricate knitting machine
Restarting lubricating interval
6.3.5 Restarting lubricating interval
1. Tap display for "Lubricate needle bed" message.
The "Current message" window appears.
2. Tap"
624 Lubricate needle bed (OIL)" message.
The message is marked with a frame. The function key for opening the
"Sen
sors" window appears at the bottom of the touch screen.
3. Call up the "Sensors" window.
4. Input "Syst. run through until lubric.".
5. Confirm input.
6. Call up "Main menu".
Oiling jac k bed
6.3.6 Oiling jack bed
Oiling the ja ck bed
Oiling the jack bed
Use a brush to apply oil to the jack bed (1).
NOTICE
If a spray gun is used for oiling, too much oil may be applied!
The suction tube becomes clogged.
Do not use a spray gun for oiling.