7 Repairing the knitting machine
Replacing parts
5. Remove two screws (2) on each side of the machine.
Releasing the needle bed (on the right: CMS 830 C, CMS 520 C+)
Releasing the needle bed (on the right: CMS 830 C, CMS 520 C+)
6. With CMS 822, CMS 803:
Release the rear needle bed for gauge E 10 - E 18
Remove the screws (3). Push the connect
ion (4) to the side. While doing
so, the impulse sensor rail is pushed to the side.
Link of the impulse sensor rail
Link of the impulse sensor rail
Remove n eedle bed or posit ion it at an angle
Remove needle bed or
position it at an angle
Position the needle bed at an angle:
Position the needle bed at an angle and secure against tilting, for e
xample
with the needle bed support (special attachment, ID 263 625).
- or -
Remove the needle bed:
Remove the needle bed from the machine with two persons.