Commands Listed in Alphabetical Order
CH<x>:PRObe:
ID? (Query Only)
This query-only command returns the type and serial of the probe that is attached
to the specified cha nnel. The channel is specified by x. The value of x can range
from 1 throug
h4.
Group
Vertical
Syntax
CH<x>:PRObe:ID?
Examples
CH2:PROBE:ID? might return :CH2:PROBE:ID:TYPE "10X";SERNUMBE R
"N/A"
, indicating that a passive 10X probe of unknown serial number is attached
to Channel 2.
CH<x>:PRObe:ID:SERnumber? (Query Only)
This query-only command returns the serial number of the probe that is attached
to the specified cha nnel. The channel is specified by x. The value of x can range
from 1 through 4.
NOTE. For L evel 0 and 1 probes, the serial n umber will be “N/A”.
Group
Vertical
Syntax
CH<x>:PRObe:ID:SERnumber?
Examples
CH1:PROBE:ID:SERNUMBER? might r eturn :CH1:PROBE:ID:SERNU MBER
"B010289"
, indicating that the serial number of the probe attached to Channel 1
is B010289.
CH<x>:PRObe:ID:TYPe? (Query Only)
This query-only command returns the type of probe that is attached to the
specified channel. The channel is specified by x. The value of x can range from 1
through 4. Level 2 (or higher) probes supply their exact product nomenclature; for
Level 0 or 1 probes, a generic ’type string’ of “nnX” is returned.
Group
Vertical
2-118 DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual