Commands Listed in Alphabetical Order
Arguments
HIGH species H
IGH polarity.
LOW species LOW polarity.
Examples
TRIGGER:A:SPI:DATA:MISO:AC TIVE HIGH sets the SPI trigger MISO polarity
to high.
TRIGGER:A:SPI:DATA:MISO:AC TIVE? might return
:TRIGGER:A:SPI:DATA:MISO:A CTIVE LOW, indicating that the SPI MISO
polarity is set to low.
TRIGger:A:SPI:DATa:MISO:LEVel
DPO7000 Series only: This command sets or queries the threshold for the SPI
MISO data source.
Group
Low Speed Serial Trigger
Syntax
TRIGger:A:SPI:DATa:MISO:LE Vel <NR3>
TRIGger:A:SPI:DATa:MISO:LE Vel?
Arguments
<NR3> species the threshold for the SPI trigger MISO data source. The range
is ±5.0.
Examples
TRIGGER:A:SPI:DATA:MISO:LE VEL 0. 0 sets the threshold for the SPI trigger
MISO data source to 0.0.
TRIGGER:A:SPI:DATA:MISO:LE VEL? might return
:TRIGGER:A:SPI:DATA:MISO:L EVEL 5.0, indicating that the threshold for
the SPI MISO data source is set to 5.0.
TRIGger:A:SPI:DATa:MISO:SOUrce
DPO7000 Series only: This command sets o r queries the MISO data source for
the SPI trigger.
Group
Low Speed Serial Trigger
Syntax
TRIGger:A:SPI:DATa:MISO:SO Urce CH<x>
TRIGger:A:SPI:DATa:MISO:SO Urce?
DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual 2-591

Table of Contents

Other manuals for Tektronix DPO70000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix DPO70000 Series and is the answer not in the manual?

Tektronix DPO70000 Series Specifications

General IconGeneral
BrandTektronix
ModelDPO70000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals