Commands Listed in Alphabetical Order
Arguments
CH<x> specifies
one of the input channels as the reset source. Input channels
are specified by x.
AUXiliary spe
cifies an external trigger (using the Auxiliary Trigger Input
connector) as the reset source.
Examples
TRIGGER:B:RESET:SOURCE CH4 sets Channel 4 as the input source for the
trigger reset.
TRIGGER:B:RESET:SOURCE? might return :TRIGGER :B:RESET:SOURCE CH1,
indicating that the current input source for the trigger reset is Channel 1.
TRIGger:B:RESET:STATE
This command sets or queries the trigger reset state for the A→B sequential State
trigger reset feature.
Group
Trigger
Syntax
TRIGger:B:RESET:STATE {HIGH|LOW}
TRIGger:B:RESET:STATE?
Related Commands
TRIGger:B:RESET:TYPe, TRIGger:B:RESET:SOUrce, TRIGger:B:RESET:
THReshold
Arguments
HIGH sets the condition for the state sequential trigger reset to high.
LOW sets the condition for the state sequential trigger reset to low.
Examples
TRIGGER:B:RESET:STATE LOW sets the condition for the state sequential trigger
reset to L ow.
TRIGGER:B:RESET:STATE? might return :TRI GGER:B:RESET:STATE HIGH,
indicating that High is the condition for the state sequential trigger reset.
TRIGger:B:RESET:THReshold
This command sets or queries the trigger threshold for the A→B sequential trigger
reset, except for the Timeout reset type.
Group
Trigger
2-612 DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual