Commands Listed in Alphabetical Order
Arguments
<NR3> is the floa
ting point number that sets the time to the pulse bit sampling
position.
Examples
MASK:MASKPRE:TRIGTOSAMP 162E-9 sets the current mask time from
the (leading edge) trigger position to the pulse bit sampling position to
162 nanoseconds.
MASK:MASKPRE:TRIGTOSAMP? might return : MASK:MASKPRE:TRIGTOSAMP
100
, indicating that the time value of the displayed mask is set to 100 nanoseconds.
MASK:MASKPRE:VOFFSet
This command sets or returns the nominal vertical offset, in volts, used to
vertically offset the input channels. The query form of this command returns the
offset value of the displayed mask. The set form of this command only affects
the current (displayed) mask.
Group
Mask
Syntax
MASK:MASKPRE:VOFFSet <NR3>
MASK:MASKPRE:VOFFSet?
Related Commands
MASK:MASKPRE:VPOS, MASK:MASKPRE:VSCAle
Arguments
<NR3> is a floating point number that sets the nominal vertical offset in volts.
Examples
MASK:MASKPRE:VOFFSET 0.0 sets the current mask nominal vertical offset
to 0.0 volts.
MASK:MASKPRE:VOFFSET? might return :MASK:MASKPREVOFFSET 1.0000,
indicating that the offset value of the displayed mask is se t to 1.0
volts.
MASK:MASKPRE:VPOS
This command sets or returns the nominal vertical position, control in divisions,
used to vertically position the input channels. The query form of this command
returns the vertical position value of the displayed mask. The set form of this
command only affects the current (displayed) mask.
Group
Mask
2-312 DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual