Commands Listed in Alphabetical Order
Examples
TRIGGER:A:PUL
SE:WIDTH?
might return
:TRIGGER:A:PULSE:WIDTH:LO WLIMIT 2.0000E-9; HIGHLIMIT
2.0000E-9;WHEN WITHIN; POLARITY POSITIVE
as the current A width
trigger parameters.
TRIGger:{A|B}:PULse:WIDth:HIGHLimit
This command sets or queries the upper limit for the width trigger. This command
is equival
ent to selecting Width Setup from the Trig menu and setting the Upper
Limit.
Group
Trigger
Syntax
TRIGger:{A|B}:PULse:WIDth :HIGHLimit <NR3>
TRIGger:{A|B}:PULse:WIDth :HIGHLimit?
Rel
ated Commands
TRIGger:{A|B}:PULse:WIDth?
Arguments
<NR3> specifies the width trigger upper limit in seconds.
Examples
TRIGGER:A:PULSE:WIDTH:HIG HLIMIT 5.0E-6 sets the upper limit of the
width trigger to 5 µs.
TRIGGER:A:PULSE:WIDTH:HIG HLIMIT? might return
:TRIGGER:A:PULSE:WIDTH:HI GHLIMIT 2.0000E-9, indicating
that the upper limit of the width trigger is set to 2 ns.
TRIGger:{A|B}:PULse:WIDth:LOWLimit
This command sets or queries the lower limit for the width trigger. This command
is equivalent to selecting Width Setup from the Trig menu and setting the pulse
Lower Limit.
Group
Trigger
Syntax
TRIGger:{A|B}:PULse:WIDth :LOW
Limit <NR 3>
TRIGger:{A|B}:PULse:WIDth :LOWLimit?
Related Commands
TRIGger:{A|B}:PULse:WIDth?
2-542 DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual