Commands Listed in Alphabetical Order
Examples
TRIGGER:A:SPI
:SCLK:ACTIVE FALL
sets the SPI SCLK polarity to fall.
TRIGGER:A:SPI:SCLK:ACTIVE ? might return
:TRIGGER:A:S
PI:SCLK:ACTIVE FALL
, indicating that the SPI SCLK polarity
is set to FALL.
TRIGger:A:SPI:SCLK:LEVel
DPO7000 Ser
ies only: This command sets or queries the threshold for the SPI
trigger SCLK.
Group
Low Speed Serial Trigger
Syntax
TRIGger:A:SPI:SCLK:LEVel <NR3>
TRIGger:A:SPI:SCLK:LEVel?
Arguments
<NR3> speci es the SPI trigger SCLK threshold.
Examples
TRIGGER:A:SPI:SCLK:LEVEL 0.0 sets the SPI SCLK threshold to 0 .0.
TRIGGER:A:SPI:SCLK:LEVEL? might return :TRIGGER:A:SPI:SCLK:LEVEL
5.0
, indicating that the SPI SCLK threshold is set to 5.0.
TRIGger:A:SPI:SCLK:SOUrce
DPO7000 Series o nly: This command sets or queries the SPI SCLK source.
Group
Low Speed Serial Trigger
Syntax
TRIGger:A:SPI:SCLK:SOUrce CH<x>
TRIGger:A:SPI:SCLK:SOUrce ?
Arguments
CH<x> species the SPI SCLK source. X can be 1, 2, 3, or 4.
Examples
TRIGGER:A:SPI:SCLK:SOURCE CH2 sets the SPI SCLK trigger source to
channel CH2.
TRIGGER:A:SPI:SCLK:SOURCE ? might return
:TRIGGER:A:SPI:SCLK:SOURC E CH4, indicating that the SPI SCLK trigger
source is set to channel CH4.
2-596 DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual

Table of Contents

Other manuals for Tektronix DPO70000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix DPO70000 Series and is the answer not in the manual?

Tektronix DPO70000 Series Specifications

General IconGeneral
BrandTektronix
ModelDPO70000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals