Commands Listed in Alphabetical Order
Examples
TRIGGER:A:PUL
SE:RUNT:POLARITY NEGATIVE
sets the polarity of the A
pulse runt trigger to negative.
TRIGGER:A:PU
LSE:RUNT:POLARITY?
might return
:TRIGGER:A:PULSE:RUNT:POLA RITY POSITIVE, indicating that the polarity
of the A pulse runt trigger is set to positive.
TRIGger:{A
|B}:PULse:RUNT:POLarity:CH<x>
This command sets or queries the polarity for the A or B pulse runt trigger for
the channel.
This command is equivalent to selecting Runt Setup from the Trig menu and then
choosing the Polarity setting for the channel.
Group
Trigger
Syntax
TRIGger:{A|B}:PULse:RUNT:P OLarity:CH<x>
{EITher|NEGAtive|POSITIVe}
TRIGger:{A|B}:PULse:RUNT:P OLarity:CH<x>?
Related Commands
TRIGger:{A|B}:PULse:RUNT:THReshold?
Arguments
POSITIVe indicates that the rising edge crosses the low threshold and the falling
edge recrosses the low threshold without either edge ever crossing the high
threshold.
NEGAtive indicates that the falling edge crosses the high threshold and the
rising edge recrosses the high threshold without either edge ever crossing the
low threshold.
EITher indicates either negative or positive polarity.
Examples
TRIGGER:A:PULSE:RUNT:POLAR ITY:CH3 NEGATIVE sets the polarity of the
Channel 3 A pulse runt trigger to negative.
TRIGGER:A:PULSE:RUNT:POLAR ITY:CH3? might return
:TRIGGER:A:PULSE:RUNT:POLA RITY:CH3 POSITIVE, indicating
that the polarity of the A pulse runt trigger is set to positive.
DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual 2-527