Commands Listed in Alphabetical Order
Syntax
TRIGger:{A|B}
:LOGIc:SETHold:CLOCk:SOUrce CH<x>
TRIGger:{A|B}:LOGIc:SETHol d:CLOCk:SOUrce?
Related Commands
TRIGger:{A|B}:LOGIc:SETHold:CLOCk:EDGE, TRIGger:{A|B}:LOGIc:
SETHold:CLOCk:THReshold
Arguments
CH<x> specifi es the input channel, which ranges from 1 through 4 for four-channel
instruments o r 1 through 2 for two channel instruments.
Examples
TRIGGER:A:LOGIC:SETHOLD:CL OCK:SOURCE CH1 specifies channel 1 as the
A logic setup and hold input.
TRIGGER:A:LOGIC:SETHOLD:CL OCK:SOURCE? might return
:TRIGGER:A:LOGIC:SETHOLD:C LOCK:SOURCE CH4, indicating that channel 4
is the clock source for the setup and hold input. For the A logic trigger.
TRIGger:{A|B}:LOGIc:SETHold:CLOCk:THReshold
This command se
ts o r qu eries the clock voltage threshold for the setup and hold
trigger. This command is equivalent to selecting Setup/Hold Setup from the Trig
menu and setting the desired Clock Level.
Group
Trigger
Syntax
TRIGger:{A|B}:LOGIc:SETHol d:CLOCk:THReshold {ECL|TT L|<NR3>}
TRIGger:{A|B}:LOGIc:SETHol d:CLOCk:THReshold?
Related Commands
TRIGger:{A|B}:LOGIc:SETHold:CLOCk:EDGE, TRIGger:{A|B}:LOGIc:
SETHold:CLOCk:SOUrce
Arguments
ECL specifies a preset ECL high level.
TTL specifies a preset TTL high level.
<NR3> is the clock level, in volts.
Examples
TRIGGER:A:LOGIC:SETHOLD:CL OCK:THRESHOLD TTL specifies the preset
TTL value as the clock threshold for the setup and hold trigger.
TRIGGER:A:LOGIC:SETHOLD:CL OCK:THRESHOLD? might return
:TRIGGER:A:LOGIC:SETHOLD:C LOCK:THRESHOLD 1.2000E+00, indicating
that the clock threshold for the setup and hold trigger is 1.2 V.
DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual 2-511