Commands Listed in Alphabetical Order
Arguments
START specifies
triggering on the start of a packet.
STOP specifi es triggering on the stop packet.
REPEATSTART specifies triggering on a repeated start of packet.
ACKMISS specifies triggering on a missing acknowledgement.
ADDRESS specifies triggering on the address.
DATA specifies triggering on the specified data.
ADDRANDDA
TA
specifies triggering on the specified data and address.
Examples
TRIGGER:A:I2C:CONDITION START sets the trigger condition for the I2C
trigger
on the start of the packet.
TRIGGER:A:I2C:CONDITION? might return :TRIGGER:A:I2C:CONDI TION
DATA
,in
dicating that the trigger condition for the I2C trigger is set on specified
data.
TRIGger:A:I2C:DATa:DIRection
DPO7000 Series only: This command sets or queries the I2C trigger condition
valid on a READ, WRITE, or either.
Grou
p
Low Speed Serial Trigger
Syntax
TRIGger:A:I2C:DATa:DIRecti on {READ|WRITE|NOCARE}
TRIGger:A:I2C:DATa:DIRecti on?
Arguments
READ specifies read as the data direction.
WRITE specifies write as the data direction.
NOCARE specifi es either as the data direction.
Examples
TRIGGER:A:I2C:DATA:DIRECTI ON WRITE sets the I2C data direction to write.
TRIGGER:A:I2C:DATA:DIRECTI ON? might return
:TRIGGER:A:I2C:DATA:DIRECT ION READ, indicating that the I2C data
direction is set on read.
DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual 2-571