Commands Listed in Alphabetical Order
TRIGGER:A:PUL
SE:WIDTH:QUALIFY?
might return
:TRIGGER:A:PULSE:WIDTH:QUA LIFY OCCURS, indicating that an A trigger
will occur if the instrument detects any of the width qualifications.
TRIGger:{A|
B}:PULse:WIDth:WHEn
This command sets or queries whether to trigger on a pulse width that falls outside
(or within) the specified range of limits. You can define or query trigger pulse
width uppe
r and lower limits using the TRIGger:A:PULse:WIDth:HIGHLimit
and TRIGger:A:PULse:WIDth:LOWLimit commands.
This comm
and is equivalent to selecting Width Setup from the Trig menu and
then choosing from the Trig When drop-down list.
Group
Trigger
Syntax
TRIGger:{A|B}:PULse:WIDth: WHEn {OUTside|WIThin}
TRIGger:{A|B}:PULse:WIDth: WHEn?
Related Commands
TRIGger:{A|B}:PULse:WIDth:HIGHLimit, TRIGger:{A|B}:PULse:WIDth:
LOWLimit
Arguments
OUTside argument causes a trigger event t
he duration of the pulse is greater
than the high limit or less than the low limit specified. The high and low
limits are specified with the
TRIGger:A:PULse:WIDth:HIGHL imit and
TRIGger:A:PULse:WIDth:LOWL imit commands respectively.
WIThin argument causes a trigger event when the duration of the
pulse is within the high and low limits. The high and low limits
are specified with the
TRIGger:A:PULse:WIDth:HIGHL imit and
TRIGger:A:PULse:WIDth:LOWL imit command respectively.
Examples
TRIGGER:A:PULSE:WIDTH:WHEN WITHIN specifies that the duration of the A
pulse will fall within defined high and low limits.
TRIGGER:A:PULSE:WIDTH:WHEN ? might return
:TRIGGER:A:PULSE:WIDTH:WHE N OUTSIDE, indicating the conditions for
generating a width trigger.
TRIGger:{A|B}:PULse:WINdow? (Query Only)
This query-only command returns the current window trigger parameters.
DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual 2-545