Commands Listed in Alphabetical Order
Syntax
MASK:MASKPRE:
HSCAle <NR 3>
MASK:MASKPRE:HSCAle?
Related Commands
MASK:MASKPRE:HTRIGPOS
Arguments
<NR3> is a floating point number that sets the mask drawing timing resolution.
Examples
MASK:MASKPRE:HSCALE 40E-9 sets the nominal timing resolution used to draw
the mask pulse shape to 40 nanoseconds per division.
MASK:MASKPRE:HSCALE? might return :MASK:MAS KPRE:HSCALE 1, indicating
that the current mask’s nominal timing resolution is to 1 nanosecond per divisions.
MASK:MASKPRE:HTRIGPOS
This command sets or returns the nominal trigger position (pulse leading edge)
used to draw the mask as a fraction of the display width. The query form of this
command returns the nominal trigger position of the displayed mask. The set form
of this command only affects the current (displayed) mask.
Group
Mask
Syntax
MASK:MASKPRE:HTRIGPOS <NR3>
MASK:MASKPRE:HTRIGPOS?
Related Commands
MASK:MASKPRE:HSCAle
Arguments
<NR3> is a floating point number in the range of 0.0 to 1.0 that sets the trigger
points as a fraction of the display width, referenced from the left edge of the
graticule. The number 0.0 represents the left edge.
Examples
MASK:MASKPRE:HTRIGPOS 0.6 sets the current mask nominal pulse leading
edge position to the sixth horizontal graticule d ivision.
MASK:MASKPRE:HTRIGPOS? might return :MASK:MASKPRE:HTRIGPOS 0.8,
indicating that the trigger position is set to eight horizontal graticule divisions.
DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual 2-309