X35 Monitor Air Seeder Setup
6.87
4. Button Options - the following are function
options available for some or all of the
assignable buttons.
a. Not Assigned - this button has no function.
b. Calibration Mode
On/Off - will enter/exit
calibration mode.
i. When in calibration mode, the tank
mounted keypad can be used to
control metering augers, as well as
to run meters to check runs when the
unit is stationary.
ii. The X35 needs to be on the Seeder
Controller screen for this to work.
iii. Tap the button to enter calibrate.
iv. To exit calibrate you need to hold
button until all 3 LED light colors
flash then goes back to amber.
c. Quick
Depth Adjustment (QDA) - raises
&
lowers the QDA.
i. Only available for the 3420 drill.
d. Tank Fill Mode On/Off - will enter fill
mode.
i. When
in fill mode, the tank mounted
keypad can be used to activate tanks
as they are filled to apply the added
weight to them.
ii. The X35 needs to be on the seeder
controller screen for this to work and
LED needs to be amber.
iii. Tap the button to enter fill mode and
LED will go green.
e. Lift Master Control - will lift & lower
the
openers if that feature is enabled and
connected.
5. Button C - on the tank mounted (calibration)
keypad
this button always functions as the
prime/reset button.
a. In calibration, press to reset meter pulses.
i. The amber LED indicates there are
pulses detected.
ii. Red indicates pulses have been
cleared.
b. When
not in calibration, this button can be
used to prime the meters.
i. They will run for the preset time if
the button is tapped.
ii. If the button is held they will
continue running.
6.8.2.2.1 Keypad LED status
1. Tank buttons
a. Red - tanks are switched off.
b. Amber - tanks are switched on but master
is
of
f.
c. Green - tanks are switched on and master
is on.
2. Master
button
a. Red
- master is not ready (something is
preventing master
turning on, see status
window).
b. Amber - master is ready and can be turned
on.
c. Gr
een - master is on.
3. Lift Master button
a. Red
- Lift Master is shut off.
b. Amber - Lift Master is turned on but
openers
are
in the lifted position.
c. Green - openers are in the lowered
position.
Note
Unused tank buttons and unassigned buttons will
have no LEDs lit up.