X35 Monitor Air Seeder Setup
6.86
f. Pack Master Control On/Off - engages &
disengages Pack Master.
g. Liquid/NH3 Manual
Override - changes
between VRC, auto and manual mode for
the Liquid/NH3 tank.
h. Fill All Tanks - adds product weight to
each
tank, based on 100% tank volume
used and density of the product in that
specific tank (hold button until all 3 LED
light colors flash then goes back to green).
i. Quick Depth Adjustment (QDA) - raises
&
lowers the QDA. Only available for the
3420 drill.
j. Prime - can be used to run meters for a
preload
time or as long as the button is
held to check runs.
5
. Tank Keys - allows you to select tank controls:
a. Virtual - the X35 console only will be
used to control the tank switches.
b. Keypad - the keypad will be used to
control the
tank switches.
c. Keypad and
Virtual - both, the X35
console and the in-cab keypad will be used
to control the tank switches.
6. Tank Rate Change Mode - allows you to
select
which tanks will be controlled when the
increase/decrease tank rate button is used. The
available options are:
a. All Tanks - applies to all enabled tanks.
b. Active Tanks - applies to only tanks that
have
the switch turned on.
c. Selected T
anks - brings up another tab
that allows you to pick specific tank(s) to
apply to, refer to Step 7.
7. Select Tank - allows you to select specific
tank(s)
that will be controlled, when the
increase/decrease tank rate button is used.
6.8.2.2 Tank Mounted (Calibration) Keypad
1. Keypad ID
- allows you to select the in-cab
keypad.
a. When selected, it will display a drop down
list with keypad IDs.
i. If there is no keypad used, select
"None".
ii.
Y
ou can confirm you have the right
keypad assigned in the cab as the
LED lights will stop flashing.
b. There is also an "Identify Keypad" button
that changes the flash sequence to confirm
you have the right one selected for the
appropriate location.
2. Identify Keypad
- when selected, led lights on
the keypad will flash green, yellow, red. Refer
to Figure 6.103.
a. Select this button again to stop flashing.
3. Assignable
Button
s - the following buttons
are able to be customized to perform various
functions. Options for each button will depend
on features that are enabled on the console.
a. Button A
b. Button B