Chapter 30 Error Disable
OLT2406 User’s Guide
268
Figure 162 Advanced Application > Errdisable > CPU protection
The following table describes the labels in this screen.
Table 110 Advanced Application > Errdisable > CPU protection
LABEL DESCRIPTION
Reason Select the type of control packet you want to configure here.
Port This field displays the port number. * means all ports.
* Use this row to make the setting the same for all ports. Use this row first and then make
adjustments to each port if necessary.
Changes in this row are copied to all the ports as soon as you make them.
Rate Limit (pkt/s) Enter a number from 0 to 256 to specify how many control packets this port can receive or
transmit per second.
0 means no rate limit.
You can configure the action that the OLT takes when the limit is exceeded. See Section 30.4 on
page 269 for detailed information.
Apply Click Apply to save your changes to the OLT’s run-time memory. The OLT loses these changes if it
is turned off or loses power, so use the Save link on the top navigation panel to save your
changes to the non-volatile memory when you are done configuring.
Cancel Click Cancel to begin configuring this screen afresh.