78.4.1 Dial Plan Rule Details
A dial plan defines the dialing patterns, such as the length and range of the digits for a telephone
number. It also includes country codes, access codes, area codes, local numbers, long distance
common-set max-size <1 ~ 256>
critical-dial-timeout <0 ~
8000> partial-dial-timeout <0
~ 32000> format <format>
Sets the dial plan table’s common configuration
settings.
These include the maximum number (from 1 to
256) of dial plans, critical-dial-timeout (from 0 to
8000 milliseconds), partial-dial-timeout (from 0 to
32000 milliseconds) and format. The format
options:
not-def: Not defined
h248: H.248 format with specific plan (table
entries define the dialing plan)
NSC: NSC format
ven-spe: Vendor specific format
C13
content-table <1 ~ 4> <token>
Configures a dialing token (rule) in the dial plan
table.
Identify a dial plan table entry number (from 1 to
4) and dial plan rule (from 1 to 28 characters).
Dial plan rules: Symbols, and Descriptions:
Multiple Rule: |, Use "|" to separate multiple
rules.
Any one numeric digit: x, Allow the user to input
any numeric digit (0~9), one 'x' means one digit
A subset of keys: [], Allow the user to input a
range of digits, for example: [1-3] or [148]
Repeat: ., Allow the user to input a repeatable
digit (above o times). For example: (12.) allows
1, 12, 122, and 1222.
Append: <:123>, Append '123' digits in the place
of the rule.
Remove: <123:>, Remove '123' digits in the place
of the rule.
Replace: <123:456>, Replace '123' digits with
'456' digits in the place of the rule.
Block: !, Type '!' at the end of the rule, to block
the number which matches the rule.
Wait Timeout to Dial: T, Type 'T' at the end of the
rule, once the dialed number is input, the call is
dialed out after the timeout.
Gateway: =gw0=,=gw3=, Type one of these at
the end of the rule and when a dialed number
matches the rule, the device transfers the call to
the gateway (0: FXS port; 3: SIP).
C13
Table 296 VoIP Dial Plan Profile Commands (continued)
COMMAND DESCRIPTION M P