Chapter 54 Basic Settings
OLT2406 User’s Guide
423
Set the port to forward BPDUs it receives.
Display the port’s settings.
54.11 Checking Installed Line Cards
The following table describes the command for checking the installed line cards on the OLT.
54.11.1 LC Status Command Example
The following example displays which line cards are installed in the OLT’s slots.
OLT2406(config-interface)# bpdu-control tunnel
OLT2406(config-interface)# exit
OLT2406(config)# exit
OLT2406# show interfaces config ge-6-1
Port Configurations:
Port No :ge-6-1
Active :Yes
Name :2406
PVID :1 Flow Control :Yes
Type :1000M Speed/Duplex :1000-full
BPDU :tunnel 802.1p Priority :0
Table 204 LC Status Command
COMMAND DESCRIPTION M P
show lc status
Displays which card type is installed in the OLT’s
slots.
E3
OLT2406# show lc status
48V power: Input-A up, Input-B down
Slot Id State Card Type Up Time
--------- ------- ----------- ----------
1 active MSC 00:09:13
2 - MSC -
3 -
4 -
5 -
6 active GPON 00:08:08