Chapter 37 OLT Registration
OLT2406 User’s Guide
296
O6 POPUP-state: When the ONT loses optical signals, the ONT goes to this state. In the meantime, the
ONT stops upstream transmission, and it will detect an LOS alarm.
O7 Emergency-Stop-state: The ONT goes to this state when it receives a Disable_Serial_Number
message. The ONT is forbidden to transmit upstream data.
37.2 The OLT Registration Screen
Use this screen to configure how you want to register the ONTs that are connected to a GPON interface
on the OLT. Click Advanced Application > OLT Registration in the navigation panel to display the screen
as shown.
Figure 180 Advanced Application > OLT Registration
The following table describes the labels in this screen.
Table 127 Advanced Application > OLT Registration
LABEL DESCRIPTION
Active Select this to enable the GPON interface settings on the selected GPON interface.
AID Choose the GPON interface that you want the settings configured here to apply to from the drop-
down list.