Chapter 79 PON DDMI
OLT2406 User’s Guide
582
CHAPTER 79
PON DDMI
79.1 Overview
This chapter shows you how to configure profiles of ONT alarm thresholds. You can also view the SFP
transceiver information and operating parameters.
79.2 PON DDMI Commands
The following section lists the commands for this feature.
Table 300 PON DDMI Commands
COMMAND DESCRIPTION M P
interface transceiver-ddmi <aid>
Enters sub-command mode for configuring the
interface transceiver threshold settings.
aid: <ge|msc|pon>-<slot>-<port>
C13
tlimit [alarm <high> <low>]
[warn <high> <low>]
Sets the temperature alarm and/or warning
threshold.
value range <-128 ~ 128> Units: degrees Celsius
C
C13
vlimit [alarm <high> <low>]
[warn <high> <low>]
Sets the voltage alarm and/or warning
threshold.
value range <0 ~ 6.55> Units: volts
C13
blimit [alarm <high> <low>]
[warn <high> <low>]
Sets the bias current alarm and/or warning
threshold.
value range <0 ~ 131> Units: mA
C13
txlimit [alarm <high> <low>]
[warn <high> <low>]
Sets the transmission power alarm and/or
warning threshold.
value range <-40 ~ 8.2> Units: dbm
C13
rxlimit [alarm <high> <low>]
[warn <high> <low>]
Sets the receive power alarm and/or warning
threshold.
value range <-40 ~ 8.2> Units: dbm
C13
no inactive
Activates the interface transceiver threshold
configuration.
C13
inactive
Disables the interface transceiver threshold
configuration.