OLT2406 User’s Guide
648
register-method template-option
<template-number>
Creates an olt OLT PON register method
template (onu-121~128).
template-number: 121~128
C13
rei-counter-th <threshold> Sets the Remote Error Indication (REI) counter
threshold.
threshold: 0~4294967295
C13
tca-status <0|1> Disables or enables the low rate Threshold
Crossing Alert (TCA) alarm.
0: disable
1: enable
C13
transceiver <type> Sets the PON link’s transceiver type (0~22).
Transceiver types:
0: LIGENT
1: LUMINENT
2: FIBERXON
3: FUJITSU
4: LIGENT_A
5: LIGENT_B
6: LUMINENT_A
7: LUMINENT_B
8: FIBERXON_A
9: FUJITSU_A
10: NEC
11: NEOPTEC
12: LIGENT_C
13: FIBERXON_B
14: FUJITSU_30537
15: NEOPHOTONICS_A
16: NEOPHOTONICS_B
17: NEOPHOTONICS_C
18: SUPERXON
19: WTD
20: DELTA
21: 1
22: 2
C13
transceiver tx-disable <0|1> Disables the PON link transceiver’s transmission.
0: enable
1: disable
C13
Table 348 OLT Configuration Commands (continued)