GD32VF103 User Manual
176
1001: Trigger rotation mode only
Note: These bits are reserved in ADC1.In sync mode, the change of configuration
will cause unpredictable consequences. We must disable sync mode before any
configuration change.
Number of conversions in discontinuous mode
The number of channels to be converted after a trigger will be DISNUM+1
Discontinuous mode on inserted channels
0: Discontinuous mode on inserted channels disable
1: Discontinuous mode on inserted channels enable
Discontinuous mode on regular channels
0: Discontinuous mode on regular channels disable
1: Discontinuous mode on regular channels enable
Inserted channel group convert automatically
0: Inserted channel group convert automatically disable
1: Inserted channel group convert automatically enable
When in scan mode, analog watchdog is effective on a single channel
0: Analog watchdog is effective on all channels
1: Analog watchdog is effective on a single channel
0: scan mode disable
1: scan mode enable
Interrupt enable for EOIC
0: EOIC interrupt disable
1: EOIC interrupt enable
0: WDE interrupt disable
1: WDE interrupt enable
0: EOC interrupt disable
1: EOC interrupt enable
Analog watchdog channel select
00000: ADC channel0
00001: ADC channel1
00010: ADC channel2
00011: ADC channel 3
00100: ADC channel 4
00101: ADC channel 5
00110: ADC channel 6
00111: ADC channel 7