5
BRIDGE MODE SETTING SCREEN
5-103
8. [Port Settings] Menu (continued)
[Port Settings]–[Controller 1–Controller 4]
M Controller Communication
Configure the communication between IP1000C.
q Encryption ………………… Select “Enable” to encrypt the communication. (Default: Disable)
• When you select “Enable,” enter the appropriate key to [Encryption Key].
Note: This setting takes effect when AMBE+2 codec is used.
w Call Type ………………… Select the type of call. (Default: Group)
• Individual: Call only specified radio.
• Group: Call all radios that belong to the specified group.
• All: Call all radios.
e Tenant Number ………… Enter the IP1000C’s Tenant number. (Default: 1)
Range: “1” to “10”
r Destination ID …………… Enter the ID of the SelCall destination. (Default: 0001)
Range: “0001” to “9999”
t My Station ID …………… Enter the station ID. (Default: 0001)
Range: “0001” to “9999”
r
t