3
CONVERTER MODE APPLICATION
3-11
3. Using an external headset (continued)
1. Configuration
Access the VE-PG3 setting screen, and set the items as shown below.
VE-PG3 (Area A)
Menu Item Setting Screen Setting Item Item Name Value
Operating Mode Operating Mode Operating Mode Operating Mode Converter
EXT I/O Port Mode EXT I/O Port Mode Combined (EXT I/O 2 (EXT2))
V/RoIP IP Line SIP Server IP Phone Number 32 (Extension Number set in the VE-PG3 in area B)
SIP Server Address 192.168.0.3 (IP address set in the VE-PG3 in area B)
SIP Service Domain
192.168.0.3 (Extension Domain set in the VE-PG3 in area B)
User ID 32 (Extension Number set in the VE-PG3 in area B)
Password (Password set in the VE-PG3 in area B)
List of SIP Server Entries Connection Status Connection successful
Extension
Connect
Extension connect Extension
(TRX1) Extension Number 301
Port Type Transceiver 1 (TRX1)
Default Call
Destination Number
302 (From Radio 1 to [EXT I/O 2])
(EXT2) Extension Number 302
Port Type [EXT I/O 2 (EXT2)]
Outgoing Line (IP Line) 32
Default Call
Destination Number
401 (From [EXT I/O 2] to IP Phone)
Incoming Call
V/RoIP Incoming
Call Setting
Receive Port 32:302 (EXT2)
Port Settings
Transceiver 1 (TRX1)
Transceiver Model: Transceiver Model IC-F5060/F6060 (default)
EXT I/O 2 (EXT2) EXT Control Terminal Input Connection Port IP Network
(EXT Control Terminal) Valid Timing Control Data Detect
Power for the Microphone Enable
Reference Level (Depending on the external device)
Input Analog Gain
Input Digital Gain
(EXT Control Terminal) Reference Level (Depending on the external device)
Output Analog Gain
Output Digital Gain
Response Waiting Time (Select a desired setting)
Restoration Waiting Time
(Notice Tone to
the Transceiver)
Calling Notice Tone (Select a desired setting)
Send Connect
Success Tone
Disconnect Notice Tone
Send Connect
Failure Tone
Tone Level
(Continued on the next page.)