6
CONVERTER MODE SETTING SCREEN
6-120
9. [Port Settings] Menu (continued)
M Voice Transmission Control from a Bridge Connection
The VOX (voice operated transmission) function automatically switches the connected transceiver to receive, when
the VE-PG3 receives the not audio signal through the network.
[Port Settings]–[Bridge 1–Bridge 4]
q Attack Time ……………… Enter the TX attack time in 5 millisecond step. It is the delay time before the
VOX switch turns ON after an audio signal is received through the network.
(Default: 1000)
Range: 5 to 2000 milliseconds
w Release Time …………… Select the RX delay time in 5 millisecond step. It is the delay time for the VOX
switch to turn OFF after no audio signal is received through the network.
(Default: 200)
Range: 5 to 2000 milliseconds
e Voice Delay ……………… Set the audio signal buffer time to prevent intermittent audio in 5 millisecond
step. (Default: 5)
Range: 0 to 500 milliseconds
r Voice Threshold ………… Set the voice threshold level. The VOX function automatically switches
between receive and transmit according to this threshold level. (Default: 70)
Range: 0 to 100 %
Lower values make the VOX function more sensitive to the audio signal.