3
CONVERTER MODE APPLICATION
3-26
5. Emergency Notice (continued)
3. Operation
When an emergency situation is detected, an emergency announcement to an external audio device and a radio is
made.
• All radios in the area must have the same settings.
[When an emergency situation occurs.]
q
Area A
When an emergency situation is detected the emergency device, the external switch automatically turns ON.
w
Area A
Any ongoing regular call and/or BGM (if connected) are cancelled, and then the emergency announcement is out-
put to the external amplifier (connected to [EXT1]) and Radio A.
e
Area A
When the external switch is turned OFF, the emergency announcement is cancelled after any stop tone, if pro-
grammed, and the BGM resumes, if connected.
Area A
Area B
An example of an emergency notice device operation
Radio A
Radio A1
VE-PG3
(192.168.0.2)
VE-PG3
(192.168.0.3)
[TRX1]
[LAN]
Extension No.
301
Extension No.
401
Audio output
(A1/A2 terminal)
Audio input
(A3/A4 terminal)
Audio input
(A3/A4 terminal)
[EXT1]
[EXT2]
IP Phone No.
32
General control input
(B3/B4 terminal)
IP telephone
(KX-UT Series)
HUB
IP
Network
Extension No.
302
Ext. AMP
Audio device
(For BGM)
Announcement
output
Emergency
device

Table of Contents