2. Double-click on the Device column.
The "Register monitor device" dialog box is displayed.
3. Under the device type, select "TS (timer set value)" or "CS (counter set value)" and enter a
given device number.
The entered number is displayed in the "Device monitor" dialog box.
4. Enter a given value under current value and press the <return> key.
The set value area is updated.
19.5.4 Method 2: Using a program (high-level instruction)
When a set value for the timer/counter is to be changed due to input conditions or for other
reasons, rewrite the value of the set value area TS of the timer/counter to be changed, using
a high-level instruction as described below.
Example: Changing the set value to U20 when input R0 turns ON
When R0 is ON, the timer set value is changed from 5 to 2 seconds.
19.5 Changing Timer/Counter Set Value in the RUN Mode
WUME-FP7CPUPGR-12 19-9