17.23 SMTPcADD (Destination Group Setting)
■
Ladder diagram
(Note 1) The above figure shows the case that S1=U100 (built-in ET-LAN in the CPU unit) and S2=U1
(connection number 1) are specified by the UNITSEL instruction. Set a desired value for [S2].
(Note 2) By copying and pasting the following text in the instruction list box of FPWIN GR7, the operand part of
the above program can be input.
SMTPcADD "GRPNO=0" "GRPNAME=Grp0" "TO=aaa@bbb.co.jp" "DOMAIN=bbb.co.jp"
■
List of operands
Operand Description
S1
Starting address of the device area that stores the string data that indicates a destination group
number, or a character constant.
S2
Starting address of the device area that stores the string data that indicates a destination group
name, or a character constant.
S3
Starting address of the device area that stores the string data that indicates a destination address
(host name), or a character constant.
S4
Starting address of the device area that stores the string data that indicates a destination address
(domain name), or a character constant.
■
Devices that can be specified (indicated by ●)
Operan
d
16-Bit device:
32-Bit
device:
Integer
Real
numbe
r
St
rin
g
Index
modifie
r
W
X
W
Y
W
R
W
L
W
S
S
D
D
T
L
D
U
M
WI
W
O
TS
C
S
TE
C
E
IX K U H SF
D
F
" "
S1 ● ● ● ● ● ● ●
S2 ● ● ● ● ● ● ●
S3 ● ● ● ● ● ● ●
S4 ● ● ● ● ● ● ●
■
Outline of operation
● This instruction configures the destination group setting.
● Before executing this instruction, use "17.22 SMTPcSV (Mail Server Setting)" or the
programming tool software "FPWIN GR7" to configure the settings of the destination server.
17.23 SMTPcADD (Destination Group Setting)
WUME-FP7CPUPGR-12 17-115