7.16 COLM (Conversion: Bit Line → Bit Column)
Ladder diagram
Available operation units (●: Available)
Operatio
n unit
bit US SS UL SL SF DF
i
List of operands
Operand Description
S The device address where the data for conversion are stored, or the constant
n
The device address where the specification for the bit position is stored, or the constant (available
data range: 0 to 15)
D Starting address of the device whose bit column is rewritten
Available devices (●: Available)
Operan
d
16-Bit device:
32-Bit
device:
(Note 1)
Integer
Real
numbe
r
St
rin
g
Index
modifie
r
(Note 1)
W
X
W
Y
W
R
W
L
W
S
S
D
D
T
L
D
U
M
WI
W
O
TS
C
S
TE
C
E
IX K H SF
D
F
" "
S
n
D
(Note 1) Only 16-bit devices, and integer constants can be modified. (Real number constants, and character
constants cannot be specified.)
Outline of operation
16 bit data rows specified by [S] are transferred to [n] bit data columns in the 16 word area
specified by [D].
Portions other than the specified bit column are not changed.
Processing
Example) Operation unit: 16 bits (US)
[i]...US
7.16 COLM (Conversion: Bit Line → Bit Column)
7-36 WUME-FP7CPUPGR-12

Table of Contents

Other manuals for Panasonic FP7 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic FP7 Series and is the answer not in the manual?

Panasonic FP7 Series Specifications

General IconGeneral
BrandPanasonic
ModelFP7 Series
CategoryController
LanguageEnglish

Related product manuals